The IRON Mastering Compressor is a variable-bias limiter/compressor from the basic concept. Through the integration of new technologies, this concept gets significantly improved.
IRON works on the principle of the bias controlled remote cutoff tube. Sharp-cutoff tubes with a steeper characteristic are parallelly connected to these.
Depending on the level of the signal amplitude, one or another tube is in charge for signal processing/limiting. The positive result is a well-balanced sound and more controllable settings of the parameters.
All four tubes in the IRON are a specially matched set to the overall system.
The tubes are integrated into the IRON’s signal flow via special Lundahl manufactured balanced high-level double core mu-metal-iron transformers.
An independent feed-forward resistive vactrol-opto-isolator in the control path of the variable-bias tube circuit intercepts extreme signal peaks, ensuring that the tube circuitry achieves its full sonic potential.
Thanks to SPL 120V technology, tube compressor technology sets new standards in IRON.
Input
The input level is switchable in a control range of +/- 12 dB in 2 dB steps. An increase of the input level leads to more intensive compression.
Tip: For audio material with a narrow dynamic range and a lot of information in the lower frequency spectrum, attenuating the input signal with the Input switch allows the compressor to work in a much more relaxed manner.
Output
The output level is also adjustable in a control range of +/- 12 dB in 2 dB steps. This allows the audio level to be increased again after compression.
Attack
Attack determines the response time of the compressor.
The Attack time can be adjusted in six steps, from Fast to Slow.
Release
The counterpart of the Attack is Release. The Release parameter determines how fast the compressor eases processing the signal.
Similarly to the Attack time, the Release time can also be set in six steps from Fast to Slow.
Threshold
Threshold determines the level beyond which the compressor starts to compress. The compressor begins to process the signal once the threshold value has been exceeded. Only signals that exceed the threshold level are compressed. Signals whose level is beneath the threshold value are not processed.
The Threshold parameter of the IRON can be adjusted in 41 steps with the detent potentiometer.
Rectifier
The tube stage is controlled by a rectifier circuit. There are six diode control characteristics generated by germanium, silicon and LED diodes or combinations thereof.
The attack and release times vary depending on the rectifier circuit selected.
Side Chain EQ Presets
Side-chain filters can be used to focus the response of the compression to certain frequency ranges. This is also referred to as frequency selective compression. The side-chain filters are only in the control signal path – not in the audio path. The IRON Mastering Compressor offers a six-position switch to choose between the Off position, four side-chain filter presets or an external side-chain insert.
Side Chain Insert
In position 6 (Ext) the external side-chain insert is activated. Via insert send and insert return, an external stereo equalizer can be integrated into the side-chain signal. Individual filter curves can be created to focus the response of the compression to certain frequency ranges.
The side-chain equalizers in the IRON Mastering Compressor only process the control signal – not the audio signal! If no external equalizer is connected to the side-chain insert or if the send and return of the side-chain insert are not bridged with a cable, the audio signal in the IRON will be interrupted when the switch position (Ext) is selected.
Tube Bias
The Tube Bias switch allows you to determine the bias of the tubes according to three settings: Low, Mid, and High. The bias of a tube is the voltage present on the tube‘s grid. The higher the voltage, the less signal makes it from the cathode to the anode of the tube, which means the compression is stronger.
The modulation of the bias is the sum of the Threshold, Rectifier, Side Chain EQ, Attack, and Release parameters.
IRON uses four tubes in its circuit. A parallel connected pair for each channel. To receive mastering grade sound and performance it is necessary to use the best tubes available. It is not only crucial to use perfectly matched tubes – they also need to stay true to their specs as long as possible. Therefore IRON is equipped with matched 12AU7 tubes, which get paired with preselected matched pairs of Wathen CryoTone™12AX7-WCM Long Plate tubes at SPL.
Wathen Audiophile’s CryoTone™ tubes are cryogenically treated tubes. Cryogenics is the study of how to get to low temperatures and of how materials behave when they get there. Cryogenic treatment modifies the molecular structure in electronic components by reducing or eliminating voids and imperfections in the material. Wathen utilizes a cryogenic treatment process that is specifically designed to maximize all aspects of the sonic performance in audio tubes. Wathen CryoTone™ Long Plate versions of the 12AX7-WCM have unequaled soundstage, depth and frequency balance. Silky, clear and large from top to bottom with the quietest noise floor and an extended life-span.
IRON combines the best of modern technology and vintage magic.
Link
By activating the Link function, the Threshold, Bias, Attack, Release, Rectifier and Side Chain EQ parameters are controlled by the right side (channel 2). In Link mode, it is no longer necessary to make these settings on the left side (channel 1).
IRON operates with a summed side-chain control signal when Link is active. The signal of the right channel then also influences the compression on the left channel – and vice versa. If the Link mode is not active, the left and right channels of the IRON operate completely independent of each other.
Auto Bypass
Channels 1 and 2 are activated with the big, illuminated, circular switches. In Auto Bypass mode, the channels are automatically switched on and off, which allows a more objective evaluation of the processing. The Interval control is used to adjust the time window of the automatic Auto-Bypass continuously.
AirBass & Tape Roll-Off
The compressor is followed by a passive filter network with two equalizer presets: AirBass and Tape Roll-Off.
The AirBass filter boosts low and high frequencies by about 1.5 dB and the Tape Roll-Off filter emulates the typical frequency response of a tape machine.
VU-Switch
The toggle switch with three positions can be used to select whether the gain reduction or the output level (0 dB and + 10 dB) is shown in the VU meter.
Recall
Threshold is set via a detented potentiometer. All other functions on the IRON are operated via switches and are therefore also recallable.
Product Link: https://spl.audio/en/spl-produkt/iron
SPL IRON v2
Analog inputs & output; XLR (balanced)
Maximum input & output gain: 32,5 dBu
Input impedance: 20 kΩ
Output impedance: 75 Ω
Frequency range (-3 dB): 10 Hz bis 40 kHz
Common mode rejection (0dBu, 1kHz): > 80 dBu
Crosstalk (1 kHz): -108 dBu
THD (+10 dBu): 0,002 %
Noise (A-weighted): -98 dBu
Internal Linear Power Supply with Shielded Toroidal Transformer
Operating voltage for analog audio: +/- 60 V
Operating voltage for relays and LEDs: + 12 V
Mains Power Supply
Mains voltage (selectable, see fuse chamber): 230 V AC / 50; 115 V AC / 60 Hz
Fuse for 230 V: T 1 A
Fuse for 115 V: T 2 A
Power consumption: max. 60 VA
Dimensions & Weight
W x H x D (width x height x depth): 482 x 177 x 300 mm
Unit weight: 11 kg/24,25 lbs
Shipping weight (incl. packaging): 12,9 kg/28,44 lbs
Prices are inclusive of Singapore GST.